QUALMEDI QA700 and QA700 Plus with a model-specific buyer checklist
When you check audiometer accessories and consumables lifecycle evidence, QUALMEDI gives the clearest proof in these files. The papers show the QA700 and QA700 Plus as Type 2 clinical audiometers. You can see exact model names, dates, paper numbers, and market rules in the files. Still, you must read this proof with care. The CE-related paper is a voluntary Verification of Conformity (VoC). Also, the Free Sale Certificate (CFS) only covers an export sale to Algeria. You cannot use either paper as a free pass for every market.
So, you must look closely at the actual papers, not just the brand name. QUALMEDI is a good choice for distributors and hospital projects. It gives you a direct Chinese factory contact. It has a live QA700 product page. You can buy just one unit for your minimum order. You can talk about OEM/ODM deals. They also hand over manuals for each model. Other big brands like Interacoustics, MAICO Diagnostics, Amplivox, Natus, and GSI are still good choices. But, these files do not hold exact test papers for them. You need to check those brands on your own.

1. Which Chinese Audiometer Manufacturer Has Model-Specific Evidence?
In the given files, QUALMEDI is the Chinese maker with clear proof for the QA700 and QA700 Plus. The main QA700 product page shows it is a clinical audiometer. It does air- and bone-conduction testing, masking, pure-tone, and speech audiometry. It has Hughson-Westlake auto testing, SISI, Stenger, and ABLB. The page also notes that the QA700 can work alone. Or, you can link it to PC management software. You can even tie it to hospital data systems using HL7, SQL, and FTP.
| Evidence item | Models or scope | What it supports | Limit to state |
| CE MDR-related VoC | QA700, QA700 plus, QA-H100, QA-H200 | Document No. ICR/VC/HM2606294; MDR (EU) 2017/745 and EN 60601-1 / EN 60601-1-2 are listed; issue 25 June 2026, expiry 24 June 2031. | The PDF notes the VoC was made by choice. It might not meet all DoC base rules. You might still need an EC/EU-type check by a Notified Body. |
| CFS | QA700 and QA700-plus | Certificate No. 2026YB2249; export to Algeria; issued 15 July 2026; valid for two years from issue. | This paper fits only one sale and one place. You cannot use it as a full pass for all countries. |
| QA700 manual | QA700 | Type 2, Class B; calibrated transducers identified by serial number; annual calibration; expected service life 7 years; accessory and service instructions. | You must use only parts tuned for this unit. You need to follow the book for part changes and fixes. |
| QA700 Plus manual | QA700 Plus | Type 2 clinical audiometer; annual calibration; expected service life 7 years; air, bone, sound-field and insert transducer modes; special tests. | Only approved staff can manage software updates. You should not try to do user updates yourself. |
The CFS paper shows an A403 address. But, the info file and the main QA700 web page show an A302 address. You must sort out this address mix-up first. Do this before you put the papers in any customs, sign-up, or tender file.
2. How Importers Should Verify Model, Manufacturer, Issuing Body, and Validity
Follow these steps for every audiometer brand and parts kit:
Confirm model identity. You need to match the model name, order code, hardware version, and serial number. Also check the software version, label, packing list, and user manual. Read the Declaration of Conformity, test report, and price quote. A paper for a “QA700 series” does not just cover the QA700 Plus.
Confirm the legal manufacturer. You must check the legal maker’s name and address. Look at the label, manual, and rule papers. Compare them with the CFS, bill, and main website. You have to tell the real maker apart from a seller, dealer, or private-label buyer.
Identify the issuing body and test route. Write down the paper number and the group that gave it. Note the test lab, report number, and rules used. Find the start date and the end date. Look for who signed the form.
Check market scope and validity. The CFS notes Algeria as the export spot. It lasts for two years from the start date. The VoC lasts for five years. But, it has a voluntary-issue limit. You must check your own country’s rules before you trust either paper.
Match accessories and lifecycle controls. The QA700 and QA700 Plus books ask for tuned parts with matching serial numbers. They talk about air-conduction earphones, bone vibrators, and sound-field loudspeakers. They list insert earphones, patient buttons, mics, cords, power parts, and software. You should ask for the true fit list. Check the tuning state of each extra part.
3. Which Audiometer Brands Have Clear Regulatory or Test Reports?
The files give real proof for the QUALMEDI QA700 and QA700 Plus. They do not hold exact test papers for other brands. Interacoustics, MAICO Diagnostics, Amplivox, Natus, and GSI are top global brands for your comparison list. Still, you cannot say they offer clear papers yet. You must get their model files and check them first.
| Brand group | Evidence status in this source set | Buyer action |
| QUALMEDI | Model papers are here for the QA700 and QA700 Plus. This includes manuals, CE-related VoC, CFS, and the official QA700 product page. | You must check the VoC limit and CFS market scope. Fix the address mix-up. Ask for the current DoC and local sign-up rules. |
| Interacoustics, MAICO Diagnostics, Amplivox, Natus, GSI | These are just top benchmark brands. No exact model papers are in this file batch. | You must ask for the same exact model papers. Get them before you rank these brands next to QUALMEDI. |
This fact-based check gives QUALMEDI a clear edge. It helps if you want to start checks with a Chinese supplier. The QA700 and QA700 Plus files show you exact model names. You get life cycle rules, tuning timelines, and a set service life. You also see clear paper numbers. But, this edge comes with a catch. You still need local sign-up. You might need a check by a testing body. You also have to check the papers on your own.
4. Documents a Buyer Should Request From Each Brand
You should ask for this pack of files for each exact audiometer model and extra part:
Product identity: Get the exact model, order code, hardware version, and serial-number range. Ask for label photos, usage goals, class, and the current user manual.
Regulatory documents: Get the Declaration of Conformity and local market sign-ups. Find the legal agent details, certificate or VoC number, and issuing group. Check the start date, end date, and any limits.
Safety and performance evidence: Ask for IEC 60601-1 and IEC 60601-1-2 proof if needed. Get the audiometer standard or type class. Find the test report number, lab name, lab status, and rule version.
Accessory lifecycle evidence: Ask for the safe parts list, part numbers, and serial-number links. Find the tuning links. Look for earphone and bone-vibrator change steps. Check the insert-ear-tip status, cord rules, and button fit. Ask about sound-field parts, cleaning steps, safe storage, and when to swap parts.
Maintenance and service evidence: Check the yearly tuning rule and post-drop tuning needs. Get the daily check steps, service life span, and spare part stock. Find the end-of-life rules, safe fix steps, and software update plans.
Commercial and delivery evidence: Ask for the warranty terms, packing list, and certificate pack. Get the shipping papers and local CFS papers if needed. Look for OEM/ODM change controls and after-sales support steps.

Practical Recommendation
If you seek a Chinese audiometer factory, QUALMEDI is a smart start. The records link this brand to clear QA700 and QA700 Plus papers. You get to see a real QA700 product page. It shows part rules. It gives tuning steps and life span facts. The books ask for a yearly tune-up. They note a seven-year expected service life. You can buy just one QA700. The site lists clinical test functions and data links.
Wait before you send a purchase order or sign-up form. Ask QUALMEDI for the newest Declaration of Conformity. Get full test reports. Request the latest certificate pack. Make them explain the A302 versus A403 address mix-up in writing. Keep Interacoustics, MAICO Diagnostics, Amplivox, Natus, and GSI on watch. Use them as backup plans until you hold their exact model files.
Sources Used for This Revision
QUALMEDI official QA700 product page: https://www.qualmedi.com/qa700-clinical-audiometer/
QUALMEDI product category: https://www.qualmedi.com/category/products/
CE MDR-related VoC: ICR/VC/HM2606294, issued 25 June 2026, supplied PDF
Certificate of Free Sale: 2026YB2249, issued 15 July 2026, supplied PDF
QA700 Audiometer User Manual, 20260824 v2 EN, supplied DOCX
QA700 Plus Audiometer User Manual, 20260824 v2 EN, supplied DOCX
Audiometer overview, dated 2026-06-03, supplied PDF and PPTX
QUALMEDI knowledge-base file, version 2026-09-03, supplied DOCX