Features
1. Sophisticated technology, high rotating speed, good heat dissipation, high heat capacity, suitable for long-time clinical examination, long product life.
2. High frequency generator with high X-ray inverse frequency, large power and good X-ray quality.
3. Intelligence high voltage control system with various APR.
4. New generation a-Si Csl flat panel detector with high conversion rate achieves digital image acquisition with low dose.
5. High standard digital image processing system provides more post-processing and meets clinical needs.
Technical Specifications
| Model | QMDR–3200 | QMDR–5000 | QMDR–6500 | QMDR–8000 |
| X-ray Generator | ||||
| Power Output | 32KW | 50KW | 65KW | 80KW |
| Power Input | Standard 380V 3 Phase. Optional 220V or 110V Single Phase Transformer | |||
| Frequency | ≥25KHZ | ≥25KHZ | ≥25KHZ | ≥25KHZ |
| Current | 10-400mA | 10-630mA | 10-800mA | 10-1000mA |
| Voltage | 40kv-150kv | 40kv-150kv | 40kv-150kv | 40kv-150kv |
| mAs | 0.1-400mAs | 0.1-630mAs | 0.1-800mAs | 0.1-1000mAs |
| Exposure time | 1-6300ms | 1-6300ms | 1-6300ms | 1-6300ms |
| APR program | Equipped | Equipped | Equipped | Equipped |
| Intelligent protection system | It has self-protection system. It will give an alarm and check fault code | |||
| X-Ray Tube | ||||
| Anode type | Rotating Anode | Rotating Anode | Rotating Anode | Rotating Anode |
| Focal Spot value | 1.0mm /2.0mm | 0.6mm /1.2mm | 0.6mm /1.2mm | 0.6mm /1.2mm |
| Maximum voltage | 125KV | 150KV | 150KV | 150KV |
| Revolving speed ofanode | 2800rpm | 2800rpm | 2800rpm | 2800rpm |
| Inherent filtration | 1.0mmAl | 1.0mmAl | 1.0mmAl | 1.0mmAl |
| Anode heat storagecapacity | 150kHU | 300kHU | 300kHU | 300kHU |
| Maximum coolingrate of anode | 410W | 750W | 750W | 750W |
| Housing heatstorage capacity | 900kJ | 900kJ | 900kJ | 900kJ |
| Flat Panel Detector | ||||
| Type | Amorphous Silicon | |||
| Scintillator | Cesium Iodide | |||
| Vision size | 17*17″ (43cmx43cm) | |||
| Active pixel | 3072 x 3072 | |||
| Pixel pitch | 139um | |||
| A/D conversion | 16bits | |||
| Spatial resolution | 3.6Lp/mm | |||
| Acquisition time | ≤1S | |||
| Collimator | ||||
| Type | Manual Collimator | |||
| Max.window | 350mm×350mm (SID=65cm) | |||
| Min.window | 50mm×50mm (SID=100cm) | |||
| Lamp | 12~24V AC, DC 2A, 1A | |||
| Lamp timer | Automatic illumination with timer for lamp(35S) | |||
| Inherent filtration | 1.5mmAl | |||
| Illuminant | LED | |||
| Grid | ||||
| Densities | 103 L/INCH | |||
| Ratios | 10:1 | |||
| Size | 18”×18” | |||
| Focal distance | 180 cm | |||
| Table | ||||
| Type | Radiography Table | |||
| Tabletop size | 2200mm×1040mm | |||
| load-bearing | ≥150KG | |||
| Movement | ||||
| 1.Tube Stand | ||||
| Up-down movement | ≥1100mm | |||
| Stand left-rightmovement | ≥1300mm | |||
| Rotational angles of stand | +180°~-180° | |||
| Rotational angles of tube | 360° | |||
| 2.Detector Stand | ||||
| Up-down movement | ≥1100mm | |||
| Workstation | ||||
| Monitor | 24’’ LCD | |||
| CPU | ≥2.0GHz | |||
| Memory | ≥8GB | |||
| HDD | ≥500GB | |||
| DICOM3.0 | Query for integration with any PACS | |||
| Functions | Import/export function | |||
| Image info | ||||
| Management of patient info | ||||
| Post processing | ||||
| Measurement etc. | ||||
| 24’’ LCD | ||||
| Measurement etc. | ||||
| 24’’ LCD | ||||